EXPERIENCE

Tank Farm and Warehouse Conceptual Engineering

Isomer performed front-end conceptual engineering for a study evaluating alternatives to develop a new finished-product tank farm at an existing chemical manufacturing facility. The objective was to replace an end-of-life field-erected storage tank with a more cost-effective configuration of shop-fabricated tanks while minimizing disruption to ongoing plant operations. The study assessed layout concepts that placed the new tank farm outside the active process area, allowing installation and tie-ins without interrupting production. Isomer's alternatives analysis compared multiple building configurations, including open-tank installations, fully enclosed tank structures, and options enclosing both the tank farm and the adjacent rail loading area. The evaluation considered constructibility, operational impact, safety, capital cost, and long-term flexibility to support informed investment decisions.

Industry
Client
Kemira Water Solutions, Inc.
Location
Indiana, USA
YEAR COMPLETED
2025
Services Performed
FEED Package
Team Members Involved
Matt Vigari
Daniel Deery, PE, SE
Riley Butler, PE